Home   
   About Us   
   Products   
   Agents   
   News   
   Contact Us   
Search:
 
General Cables

EPDM (Silane XL)

SX505:CM401 or CM493
Silane crosslinkable EPDM for low and medium voltage cable insulation.
Special Characteristics
A silane crosslinkable rubber compound, curable when exposed to moist conditions. The compound is processed in the same way as a non-curable rubber giving good extrudability at high output rates. The graft component SX5O5 is mixed with a crosslinking catalyst masterbatch CM493 or CM497 generally in the ratio 95:5. Compound SX5O5:CM493 or CM497 passed type tests for use at up to and including 33 kV.

Density
g/cm²
Tensile Strength
N/mm²
Elongation % General Notes View Datasheet

0.9 9 350 Use up to 36kV

SX505NT:CM401 or CM493
Silane crosslinkable tree retardant EPDM for low and medium voltage cable insulation.
Special Characteristics
A silane crosslinkable tree retardant rubber compound, curable when exposed to moist conditions. The compound is processed in the same way as a non-curable rubber giving good extrudability at high output rates. The graft component SX505NT is mixed with a crosslinking catalyst masterbatch CM401 generally in the ratio 95:5. The graft compound contains a non-staining stabiliser and a demonstrably effective tree retardant, giving outstanding long-term retention of dielectric strength. SX505NT is intended for use at up to and including 36 kV.

Density
g/cm²
Tensile Strength
N/mm²
Elongation % General Notes View Datasheet

0.9 9 350 Use up to 36kV incorporates a tree retardant

SX510:CM493 or CM497
Silane crosslinkable EPDM for flexible low voltage cable insulation.
Special Characteristics
A silane crosslinkable rubber compound, curable when exposed to moist conditions. The compound is processed in the same way as a non-curable rubber giving good extrudability at high output rates. The graft component SX510 is mixed with a crosslinking catalyst masterbatch CM493 or CM497 generally in the ratio 95:5. Compound SX51O:CM493 or CM497 has been approved for use at 1kv and has improved flexibility over other AEI EPDM compounds.

Density
g/cm²
Tensile Strength
N/mm²
Elongation % General Notes View Datasheet

0.9 9 350 Flexible for LV insulation

SX554:CM493 & SX554:CM497
Silane crosslinkable EPDM for flexible low voltage cable insulation.
Special Characteristics
A silane crosslinkable rubber compound, curable when exposedto moist conditions. The compound is processed in the same wayas a non-curable rubber giving good extrudability at high outputrates. The graft component SX554 is mixed with a crosslinkingcatalyst masterbatch CM493 or CM497 generally in the ratio95:5. Compound SX554:CM493 or CM497 has been approvedfor use at 1kV and has improved flexibility over other AEI EPDMcompounds.

Density
g/cm²
Tensile Strength
N/mm²
Elongation % General Notes View Datasheet

0.90 9 420 Low Voltage Cable Insulation

Tracking Resistant Sheathing (Silane XL)


SX524:CM424 or CM424/1
Tough electrical tracking resistant crosslinkable sheathing grade suitable for ADSS and other outdoor application.
Special Characteristics
A silane crosslinkable sheathing compounds curable by exposure to moist conditions. The graft component SX524 is mixed with a crosslinking catalyst masterbatch CM424/1 or CM424 generally in the ratio 95:5. The compound has been specially developed for cables, in particular optical fibre ADSS (all dielectric self-supporting) communication cables, to be installed on overhead power distribution networks. The material has excellent tracking and UV resistance, suitable for outdoor use.

Density
g/cm²
Tensile Strength
N/mm²
Elongation % General Notes View Datasheet

1.4 10 300 For ADSS cable

Flexible Sheathing (Silane XL)

SX541:CM401
Flexible sheathing compound.
Special Characteristics
A Silane crosslinkable flame retardant flexible insulation and sheathing compound designed to offer TPE properties at lower cost. The graft component SX541 is mixed with a crosslinking catalyst masterbatch CM401 generally in the ratio 95:5. The compound is processed in the same way as non-curable TPE compounds, giving good extrudability at normal output rates, with crosslinking off-line when exposed to moist conditions.

Density
g/cm²
OI Tensile Strength
N/mm²
Elongation % General Notes View Datasheet

1.18 25 10 580 Similar to TPE contains halogen

SX552:CM424
Flexible Silane crosslinkable Polythylene for low voltage cable insulation.
Special Characteristics
A silane crosslinkable Polyethylene compound, curable when exposed to moist conditions. The compound is processed in the same way as a non-curable rubber giving good extrudability at high output rates. The graft component SX552 is mixed with a crosslinking catalyst masterbatch CM424 generally in the ratio 95:5. Compound SX552:CM424 has been approved for use at 1kV and has improved flexibility over other AEI Polyethylene Compounds.

Density
g/cm²
Tensile Strength
N/mm²
Elongation % General Notes View Datasheet

0.88 9.5 600 Use up to 1kV

SX558:CM401
Ambient cure silane crosslinkable polyethylene for lowvoltage power cable insulation.
Special Characteristics
A silane crosslinkable polyethylene compound for insulation ofpower cables and heating cables, possessing outstandingextrudability at high output rates. The graft component SX558 ismixed with a crosslinking catalyst masterbatch CM401 generallyin the ratio 95:5. SX558:CM401 compound can also be cured atambient temperatures and is specifically designed for small andsector shaped cables.

Density
g/cm²
Tensile Strength
N/mm²
Elongation % General Notes View Datasheet

0.93 19 450 Low Voltage Cable Insulation

Process Plus SX522C:CM401
Ambient cure silane crosslinkable polyethylene for low voltage power cable insulation.
Special Characteristics
A silane crosslinkable polyethylene compound for insulation ofpower cables and possessing outstanding extrudability at highoutput rates. The graft component SX522C is mixed with acrosslinking catalyst masterbatch CM401 generally in the ratio95:5. Process Plus SX522C:CM401 shows minimum point anddie drool, low scorch characteristics and high productionefficiency. This process plus SX522C:CM401 compound can alsobe cured at ambient temperatures and is specifically designed forpower cables.

Density
g/cm²
Tensile Strength
N/mm²
Elongation % General Notes View Datasheet

0.92 18 450 Low Voltage Cable Insulation

 


Previous Page
1 2 3  


Products
  General Cables
  Automotive
  Heat Shrinkable
  Injection Moulding
  Pipe
  Reaction Modified
 

You will need to have Acrobat Reader installed on your computer to view the datasheets on the product pages